Knowledge

Glossary

Plain-language definitions of 240+ industry terms: carpets and rugs (cut pile, loop pile, hand tufted, hand knotted, Axminster), raised floors, vinyl, pre-insulated phenolic and PIR ducts, insulation, waterproofing, lighting and industrial chemicals.

241 terms

Raised floors (25)

Calcium sulphate panel
A dense, solid panel made from high-density calcium sulphate (often fibre-reinforced). Quiet underfoot and very stiff; nGroove uses it with grooved, interlocking edges for stone and porcelain bonded directly.
Chemical anchoring
Fixing pedestal bases to the slab with a structural adhesive. Suited to lower floor heights.
Concentrated load · also Point load
The load a panel carries on a small area (a 25 × 25 mm indenter in the CISCA test), like a chair leg or cabinet foot, without exceeding the allowed deflection. Nord Floors grades run from 3.7 to 11.1 kN.
Deflection
How far a panel bends under load. Load ratings are tied to a maximum permitted deflection, not only to failure.
Edge trim
A plastic or metal edge band around a panel that protects the edge, keeps finishes neat and helps panels sit tight in the grid.
Finished floor height (FFH)
The distance from the top of the structural slab to the top of the finished floor surface, including the panel and its finish.
Floor box
A recessed box set into a panel holding power, data and AV outlets, with a lid flush to the floor finish.
Floor void · also Plenum void
The space between the slab and the underside of the panels, used for cabling, pipework and, in data centres, as an air plenum.
Grommet
A cut-out with a brush or cover in a panel that lets cables pass up to desks while limiting air loss and debris.
Impact load
The load a panel survives when a weight is dropped onto it, simulating dropped tools and equipment during fit-out.
Interlocking groove edge
Panel edges machined with a tongue-and-groove profile so neighbouring panels lock together. It stops panels shifting under rigid finishes such as stone and porcelain.
Load grade
The named rating of a panel (for example 4.5 kN) that tells the specifier which concentrated, uniform and rolling loads it carries.
Mechanical anchoring
Fixing pedestal bases to the slab with bolts or anchors. Used for taller floors and where lateral loads are higher.
Panel lifter
A suction tool used to lift panels out of the grid without damaging edges or finishes. Double-cup lifters are used for heavy and stone-finished panels.
Pedestal
The adjustable steel support under the corners of the panels. A threaded stem sets the finished floor height, and the base is fixed to the slab with adhesive or mechanical anchors.
Pedestal head
The top plate of a pedestal that carries the corners of four panels. Heads are often fitted with a conductive or sound-deadening gasket and locate the panels in the grid.
Raised access floor · also Access floor, Raised floor, False floor
A floor of removable panels on adjustable pedestals, built above the structural slab so cables, data, power and air can run underneath and be reached at any time by lifting a panel.
Ramp and step
Purpose-made ramps and steps that bring people and equipment from the slab or corridor level up to the raised floor.
Rolling load
The load a panel withstands from a wheel rolling across it (pallet trucks, server racks on castors, MEWPs) for a set number of passes, typically 10 and 10,000.
Steel cementitious panel
A panel made of a welded steel shell filled with a lightweight cementitious core. Strong, non-combustible and the basis of nSteelCement, nHPL and nSDV.
Stringer
A horizontal bar that connects pedestal heads. Stringers add lateral stability on higher floors, under heavy rolling loads and in data centres.
Stringerless system
A raised floor where panels sit directly on pedestal heads with no stringers. Quicker to install and fully open underneath; suited to lower floor heights and office loads.
Ultimate load
The load at which a panel fails in test. Rated loads are set well below it so the floor keeps a wide safety margin.
Uniformly distributed load (UDL)
The load spread evenly over the whole floor area, in kN/m², such as storage, dense furniture or battery rooms.
Woodcore panel · also Chipboard panel
A panel with a particleboard core, usually wrapped in steel or aluminium foil. Lighter and cheaper but more sensitive to humidity and water than steel cementitious or calcium sulphate panels.

Data centres (13)

Aisle containment
Doors and roof panels that enclose a hot or cold aisle so supply and return air cannot mix, improving cooling efficiency.
Antistatic HPL
A factory-applied high pressure laminate finish that limits static build-up, used on nHPL panels in server rooms and data centres.
CRAC / CRAH
Computer room air conditioner / air handler: the cooling units that supply cold air into the underfloor plenum.
Damper
An adjustable plate under a perforated panel or grille that throttles airflow to balance cooling across the room.
Earth bonding
Connecting the raised floor understructure to the building earth so static and fault currents have a safe path to ground.
Electrostatic discharge (ESD)
A sudden flow of static electricity between two objects. ESD flooring controls it to protect sensitive electronics.
Grille panel
A panel with a much larger open area than a perforated panel, for high-density racks that need more air.
Hot aisle / cold aisle
A rack layout where fronts face fronts (cold aisle, fed from perforated panels) and backs face backs (hot aisle), so hot exhaust air does not mix with cold supply air.
Open area
The percentage of a perforated or grille panel that is open to airflow. More open area means more air at the same underfloor pressure.
Perforated panel
A raised floor panel with openings (typically about 25% open area) that lets cold air from the floor void rise to the equipment in front of it.
Static dissipative vinyl
A vinyl finish that drains static charge to earth in a controlled way, used on nSDV panels in control rooms and electronics areas.
Underfloor plenum
The pressurised air space beneath a raised floor that distributes cooling air from CRAC/CRAH units to perforated panels and grilles.
Vision panel
A raised floor panel with a framed glass top so services in the floor void can be inspected without lifting a panel.

Carpets & rugs (67)

80/20 wool-nylon
The classic woven-carpet blend of 80% wool and 20% nylon: the look and feel of wool with added abrasion resistance.
Ashlar / brick installation
Laying tiles in staggered rows, offset by half a tile, like brickwork.
Axminster
A woven carpet in which each tuft is inserted individually during weaving, so almost any number of colours and patterns can be made. The classic carpet for hotels, palaces, majlis and mosques.
Bamboo silk
A trade name for viscose made from bamboo pulp, used for lustrous accents in hand-tufted and hand-knotted rugs.
Bfl-s1
A European reaction-to-fire class for floor coverings under EN 13501-1: Bfl is a high class for combustible floorings, s1 means low smoke.
Bitumen backing
A heavy bitumen-based backing used on many carpet tiles for dimensional stability and lay-flat performance.
Broadloom · also Wall-to-wall carpet
Carpet made in wide rolls, typically 4 or 5 m, and fitted wall to wall. Fewer seams and a softer, more continuous look than tiles.
Carpet tile · also Modular carpet
Carpet made in small squares or planks (commonly 50 × 50 cm) with a stable backing. Tiles can be lifted individually, which suits raised access floors and offices.
Carving
Cutting channels or levels into the pile of a hand-tufted rug to outline the design and add depth.
Castor chair suitability
A rating showing whether a carpet withstands office chairs on castors without visible wear, tested under EN 985.
Critical radiant flux (CRF)
A flooring fire test (ASTM E648 / NFPA 253) that measures how far flame spreads across a floor covering. Results are given as Class I or Class II.
Crushing
Permanent flattening of pile under traffic or furniture. Denser constructions and resilient fibres resist it.
Cut and loop
A carpet combining cut and looped tufts to create texture or a pattern in a single colour.
Cut pile
Pile whose loops are cut so each tuft stands as two yarn ends. Softer and more luxurious; it shows footprints and shading more than loop pile.
Dimensional stability
How well a carpet tile keeps its size and stays flat with changes in temperature and humidity. Important in air-conditioned buildings and on raised floors.
EN 1307 use class
The European classification of textile floor coverings by traffic: classes 21–23 for domestic use and 31–33 for commercial use (moderate, general, heavy).
Felt backing
A fibrous backing on some carpet tiles and broadloom that adds comfort and acoustic absorption.
Flatweave · also Kilim, Dhurrie
A rug woven with no pile: the pattern is formed by the weft threads themselves. Light, reversible in many cases, and easy to clean.
Frieze
A cut pile with highly twisted, curly yarns. It hides footprints and wears well.
Gauge
In tufted carpet, the distance between needles across the width (for example 1/10 inch or 1/8 inch). Finer gauge means more rows of tufts and a denser carpet.
Hand tufting
Making a carpet or rug by shooting yarn through a stretched cotton backing cloth with a hand-held tufting gun, following the design drawn on the cloth. The back is then latexed and covered with a secondary cloth. Allows any design, colour count and shape.
Hand-knotted rug
A rug woven on a loom by tying each pile knot by hand around the warp threads. The slowest and most durable construction; quality is often judged by knots per square inch.
Heat-setting
Setting the twist of a yarn with heat so tufts keep their shape and the carpet keeps its texture in use.
Knots per square inch (KPSI)
The knot density of a hand-knotted rug. Higher KPSI allows finer detail and usually means more weaving time.
Latex backing
The latex coating applied to the back of a tufted carpet to lock the tufts in place and bond the secondary backing.
Loop pile · also Level loop
Pile left as uncut loops. Hard-wearing and resistant to crushing, which makes it common in offices and corridors.
Machine tufting
Making carpet by punching yarn through a primary backing with rows of needles, then locking the tufts with a latex coat and a secondary backing. Most commercial carpet is made this way.
Majlis carpet
A carpet or rug designed for a majlis or reception room, often custom-made in Axminster or hand-tufted construction to suit the room and furniture layout.
Monolithic installation
Laying carpet tiles all in the same pile direction so the floor looks like broadloom.
Multi-level loop
Loop pile made at two or more heights to create a sculpted, textured pattern.
New Zealand wool
Wool from New Zealand flocks, valued in carpet for its whiteness (it takes dye well), strength and resilience.
Nylon (polyamide)
The most widely used commercial carpet fibre: resilient, abrasion-resistant and easy to clean. Solution-dyed nylon resists fading and bleaching.
Persian knot · also Asymmetrical knot, Senneh knot
An asymmetrical knot wrapped around one warp and passed under the next. It allows very fine, curved designs.
Pile
The visible surface yarn of a carpet that you walk on, standing up from the backing.
Pile density
How closely the tufts are packed, often expressed as pile weight divided by pile height. Denser carpet resists crushing and wears better.
Pile height
The height of the pile above the backing, in millimetres. Taller is softer but not automatically more durable.
Pile reversal · also Watermarking
A permanent form of shading where areas of cut pile lean the opposite way and look darker. It cannot be predicted or prevented by manufacturing.
Pile weight · also Face weight
The weight of pile yarn per square metre (g/m²) or per square yard (oz/yd²), excluding the backing. A key quality marker together with density.
Pill test
A small-source ignition test (ASTM D2859 / 16 CFR 1630) that every carpet sold in the US must pass.
Pitch
In woven carpet, the number of tufts per 27 inches across the width (for example 7 or 8 pitch). Higher pitch means a finer weave.
Polyester (PET)
A soft synthetic fibre with good colour clarity, often used in residential carpets and rugs.
Polypropylene (olefin)
A low-cost synthetic fibre that is stain- and moisture-resistant but less resilient than nylon. Common in budget tiles and rugs.
Pom-pom
A small yarn sample used to approve each colour before a custom carpet is made.
Primary backing
The fabric the pile is tufted into. In machine tufting it is usually polypropylene; in hand tufting it is a stretched cotton cloth.
Quarter turning
Laying carpet tiles with each tile turned 90° from its neighbour, so the pile direction changes and the floor reads as a checkerboard texture.
Rows
In woven carpet, the number of tuft rows per inch along the length. With pitch, it sets the fineness of an Axminster or Wilton.
Saff carpet · also Mosque carpet, Prayer-row carpet
Carpet patterned in rows (saff) so worshippers stand in straight lines aligned to the qibla. Usually Axminster or machine-tufted broadloom.
Saxony
A dense cut-pile carpet with straight, twisted tufts, giving a smooth, velvety surface. Mostly residential and hotel rooms.
Secondary backing
The second fabric laminated to the back of a tufted carpet to add stability and protect floors. Commonly jute, polypropylene (ActionBac-type) or cotton cloth for hand-tufted rugs.
Shading
Light and dark areas that appear in cut pile when tufts lean in different directions. A natural property of cut pile, not a defect.
Shag
A long, loose cut pile, usually more than 25 mm high. Decorative, not suited to heavy traffic.
Shedding
Loose fibres coming off a new carpet, mostly from spun (staple) yarns such as wool. It reduces with vacuuming.
Solution dyeing
Adding colour to a synthetic fibre while it is still liquid, before extrusion, so the colour runs right through the yarn and resists fading and cleaning chemicals.
Sprouting
A single tuft rising above the pile surface. It is trimmed level with scissors, never pulled.
Stitch rate
In tufted carpet, the number of tufts per unit length along each row. With gauge, it sets tuft density.
Strike-off
A small sample woven or tufted in the final colours and design, for approval before full production.
Tackifier · also Release adhesive
A pressure-sensitive adhesive that holds carpet tiles in place but lets them be lifted, essential on raised access floors.
Total weight
The weight of the whole carpet per square metre, including backing. Useful for logistics, but pile weight and density say more about wear.
Tufts per square metre
The total tuft density of a carpet, a direct way to compare constructions made on different machines.
Turkish knot · also Symmetrical knot, Ghiordes knot
A symmetrical knot wrapped around two warps with both ends coming up between them. Sturdy and common in Anatolian and Caucasian rugs.
Underlay · also Carpet pad
A cushion layer under broadloom that adds comfort, acoustic performance and carpet life.
Velvet pile · also Plush
A very dense, short cut pile with little twist, giving a smooth, luxurious finish that shows shading.
Viscose (art silk)
A regenerated cellulose fibre with a silk-like sheen, used for highlights in rugs. Beautiful but sensitive to water and traffic.
Warp
The lengthwise threads stretched on a loom. In woven and knotted carpets the warp ends often form the fringe.
Weft
The crosswise threads woven over and under the warp to bind the carpet together.
Wilton
A woven carpet in which continuous yarns run through the backing and are raised into pile only where a colour is needed. Dense and hard-wearing, with a more limited colour count than Axminster.
Wool
A natural fibre that is resilient, naturally flame-resistant and keeps its appearance for a long time. Used in premium Axminster and hand-tufted carpets.

Vinyl & hard floors (16)

Barrier matting zones
The three zones of an entrance mat system: an outdoor scraper zone, a scraping and drying zone, and an indoor drying zone.
Click lock
A profiled edge that lets planks lock together without adhesive, forming a floating floor.
Dryback
Vinyl tiles or planks that are glued down to the subfloor rather than clicked together.
Engineered wood
A wood floor with a real hardwood top layer bonded to a stable plywood or softwood core.
Entrance matting
A mat system at building entrances that scrapes and absorbs dirt and water before it reaches the main floor.
Heterogeneous vinyl
Vinyl built in layers, with a printed design under a clear wear layer.
Homogeneous vinyl
Sheet or tile vinyl with the same composition through its full thickness, so the pattern does not wear off. Common in hospitals.
LVT (luxury vinyl tile)
Vinyl tiles and planks with a printed design layer and a clear wear layer, made to look like wood or stone. Glue-down or click versions are available.
Parquet
Wood flooring laid in a geometric pattern such as herringbone or chevron.
Pendulum test value (PTV)
A measure of slip resistance from a pendulum test (BS 7976 / EN 16165). 36 or more is generally regarded as low slip potential.
Self-levelling compound
A cement-based screed poured over a slab to make it flat and smooth before resilient flooring is laid.
Slip resistance (R rating)
A ramp-test classification of floor slip resistance under DIN 51130, from R9 (lowest) to R13 (highest).
SPC (stone plastic composite)
A rigid click-fit vinyl plank with a core of limestone powder and PVC. Very stable and water-resistant, laid as a floating floor.
Subfloor moisture
Moisture rising from a concrete slab. It must be within the flooring maker's limits before vinyl or wood is laid, or adhesives can fail.
Wear layer
The clear protective top layer of vinyl flooring, measured in mm. Thicker wear layers last longer in commercial traffic.
WPC (wood plastic composite)
A rigid vinyl plank with a foamed PVC core containing wood or wood-like fillers. Softer and warmer underfoot than SPC.

HVAC ducts (25)

Air leakage class
How airtight a duct system is. EN 16798-3 / EN 1507 classes run from A (leakiest) to D (tightest); SMACNA uses leakage classes in the US. Pre-insulated ducts can reach the tighter classes.
Air velocity
How fast air moves through a duct, in m/s. Higher velocity allows smaller ducts but adds noise and pressure loss.
ASTM E84 · also UL 723
The tunnel test that gives a surface burning rating: a flame spread index and a smoke-developed index. Duct materials in the region are often required to be Class A (flame spread 25 or less, smoke 50 or less for ducts).
CNC duct fabrication
Cutting pre-insulated duct panels on a computer-controlled machine for accurate grooves, folds and fittings that match the drawings.
Condensation risk
Moisture forming on a cold duct when its surface drops below the dew point of the surrounding air. Insulation thickness is chosen to keep the outer surface above it.
Dew point
The temperature at which air becomes saturated and water starts to condense. Humid coastal air in Jeddah or Dammam has a high dew point.
Duct board
Rigid insulation boards (fibreglass or foam) that are cut and folded into ducts. Phenolic and PIR panels are the modern foam-based form.
Duct lagging
Insulation wrapped around the outside of metal ductwork after installation, such as mineral wool or elastomeric foam.
Equal friction method
A duct sizing method that keeps the pressure loss per metre the same throughout the system.
Fibre-free core
Insulation with no loose fibres (such as phenolic or PIR foam), so no fibres can enter the airstream.
Fire damper
A device in a duct that closes automatically to keep fire from spreading through a fire-rated wall or floor.
Galvanised steel ductwork · also GI duct, Sheet metal duct
Traditional ductwork made from galvanised sheet steel, installed first and insulated separately on site with a second fix.
Grip flange · also Invisible flange
A profiled aluminium flange used to join pre-insulated duct sections, often with a bayonet cleat.
Kingspan KoolDuct
Kingspan's premium pre-insulated ductwork system made from rigid phenolic panels with aluminium facings. Kingspan reports it was the first rigid phenolic pre-insulated duct to be UL 181 listed as a Class 1 Air Duct.
Kingspan PalDuct
Kingspan's pre-insulated duct panel range for the Middle East, made in Dubai. It includes PalDuct PIR and PalDuct Phenolic panels, fabricated into ductwork by approved fabricators.
PalDuct PIR 20P80
A 20 mm Kingspan PalDuct PIR panel (4000 × 1200 mm). Kingspan's data sheet rates ducts made from it for -25 °C to +80 °C, up to 1000 Pa and 15 m/s.
PalDuct PIR 30P200
A 30 mm Kingspan PalDuct PIR panel (4000 × 1200 mm) for higher pressures and air speeds than 20P80, including outdoor runs.
Phenolic duct
A pre-insulated duct made from rigid phenolic foam panels. Phenolic has very low thermal conductivity and strong fire performance, so the walls can be thin.
PIR duct
A pre-insulated duct made from rigid polyisocyanurate (PIR) foam panels. A cost-effective pre-insulated option with low thermal conductivity.
Pre-clad duct
Pre-insulated ductwork with a tougher outer cladding for exposed or outdoor runs, such as Kingspan KDuct.
Pre-insulated duct · also PI duct, Pre-insulated ductwork
HVAC ductwork fabricated from rigid insulation panels with aluminium facings on both sides, so the duct and its insulation are one lightweight piece installed in a single fix.
Static pressure
The pressure inside a duct pushing outward on its walls, in pascals. Duct panels are rated for a maximum operating pressure.
Tie rod reinforcement
Rods fixed across large pre-insulated ducts to stop the walls bowing under pressure.
UL 181
The Underwriters Laboratories safety standard for factory-made air ducts and air connectors. A Class 1 listing covers flame spread, smoke and other tests, and is widely asked for in the Middle East.
Volume control damper (VCD)
An adjustable blade in a duct used to balance airflow between branches.

Insulation & roofing (16)

Inverted roof
A flat roof where the insulation sits above the waterproofing, protecting the membrane from heat and UV.
Kingspan Kooltherm K10
A Kingspan phenolic insulation board for soffits, with a facing suited to exposed ceilings such as car parks.
Kingspan Thermaroof TR27
A Kingspan PIR roof insulation board for flat roofs under waterproofing membranes.
Mineral wool
Stone wool or glass wool insulation: non-combustible, good for acoustics, but thicker than foam boards for the same U-value.
Phenolic insulation
A closed-cell rigid foam insulation with very low thermal conductivity, used in Kingspan Kooltherm boards and phenolic duct panels.
PIR insulation · also Polyisocyanurate
A rigid thermoset foam insulation, used in Kingspan Thermaroof TR27 roof boards and PIR duct panels.
R-value
Thermal resistance: how well a layer resists heat flow. Thickness divided by lambda gives the R-value in m²K/W; US values are quoted per inch in imperial units.
SBC 601 / 602
The Saudi Building Code energy conservation requirements for residential (602) and non-residential (601) buildings, which set maximum U-values for roofs, walls and floors.
Soffit insulation
Insulation fixed to the underside of a slab, for example over car parks or open undercrofts, to cut heat flow into the rooms above.
Tapered insulation
Insulation boards cut to a fall so a flat roof drains to its outlets without a screed to falls.
Thermal bridge
A spot where heat bypasses the insulation, such as a steel beam or slab edge, raising energy use and condensation risk.
Thermal conductivity (lambda)
How well a material conducts heat, in W/m·K. Lower lambda means a thinner board for the same U-value.
U-value
How much heat passes through a building element, in W/m²K. Lower is better insulated.
Vapour control layer (VCL)
A membrane that limits water vapour moving into the insulation, where it could condense.
Warm roof
A flat roof with the insulation above the deck and below the waterproofing, keeping the structure warm and the dew point outside it.
XPS (extruded polystyrene)
A rigid closed-cell foam board with good moisture resistance, often used in inverted roofs and below ground.

Waterproofing (11)

Bituminous membrane · also Torch-on membrane
A modified bitumen sheet (APP or SBS) laid by torching or self-adhesion, often in two layers.
Crystalline waterproofing
A treatment that reacts with water and cement in concrete to grow crystals that block capillary pores.
EPDM
A synthetic rubber membrane used for roofs and ponds, joined with tapes or adhesives.
Flood test
Filling a waterproofed area with water for a set time to check for leaks before it is covered.
Hot-air welding
Joining thermoplastic membrane laps (TPO, PVC) by melting them together with hot air, creating a seam as strong as the sheet.
Liquid-applied membrane
A waterproofing coating applied as a liquid that cures into a seamless membrane, good around details and penetrations.
PVC membrane
A single-ply roofing membrane made from plasticised PVC, with welded seams.
Solar reflectance index (SRI)
How well a roof surface reflects sunlight and sheds heat. White TPO roofs score high, keeping roofs cooler in the Saudi sun.
TPO membrane
Thermoplastic polyolefin: a single-ply roofing membrane with hot-air welded seams, reflective and UV-resistant.
Upstand
The part of a roof membrane turned up a wall or parapet, normally at least 150 mm above the finished roof surface.
Waterproofing membrane
A continuous layer that stops water passing through a roof, basement, wet room or podium.

Expansion joints & louvres (10)

Expansion joint · also Movement joint
A deliberate gap between parts of a structure that lets them move with temperature, shrinkage and settlement. A joint cover bridges it on floors, walls, ceilings and roofs.
Fire barrier
A fire-resistant insert under a joint cover that keeps fire-rated walls and floors continuous across the joint.
Free area
The open area of a louvre through which air can pass, as a percentage of the face area.
Joint cover profile
The aluminium, stainless steel or rubber profile that bridges an expansion joint while allowing the movement.
Joint movement capacity
How far a joint cover can move, given as ± mm or as a percentage of the joint width.
MIGUA
A German maker of expansion joint profiles, now part of the mageba group, with ranges such as MIGUTEC, MIGUTRANS, MIGUTAN, MIGUMAX and MIGUPREN.
Performance louvre
A façade louvre tested for airflow and rain resistance, for plant rooms and ventilated façades.
Rain defence class
A classification (EN 13030) of how well a louvre keeps out driven rain, from class A (best) to D.
Sand trap louvre
A louvre with deep, closely spaced blades that catches airborne sand and dust, used on plant rooms in desert climates.
Seismic joint
A wide expansion joint designed to take large movements in an earthquake, with covers that move in several directions.

Lighting (16)

Beam angle
The spread of light from a spot or downlight, in degrees. Narrow beams accent; wide beams wash.
BS 1363 socket
The British-style 13 A three-pin socket used in Saudi Arabia, often with a built-in switch.
Colour rendering index (CRI)
How faithfully a light shows colours compared with daylight, out of 100. Offices need CRI 80 or more.
Colour temperature (CCT)
How warm or cool white light looks, in kelvin. 3000K is warm, 4000K neutral, 6500K cool.
DALI
Digital Addressable Lighting Interface: a protocol to switch, dim and group individual fittings.
Driver
The electronic unit that powers an LED at the right current and, if dimmable, controls its output.
Efficacy (lm/W)
How much light a fitting produces per watt of power. Higher is more efficient.
EN 12464-1
The European standard for lighting of indoor workplaces, setting lux, glare and colour rendering targets for each type of room.
Flicker
Rapid variation in light output. Good LED drivers keep it low to avoid eye strain and camera banding.
IP rating
Ingress protection: two digits rating protection against dust and water (for example IP65 for outdoor or wet areas).
Linear light
A long, slim fitting that can be joined into continuous lines, recessed, surface-mounted or suspended.
Lumen
The total amount of visible light a source gives out.
Lux
The amount of light falling on a surface. Offices typically need 500 lux on desks.
Magnetic track
A low-voltage track recessed or surface-mounted in the ceiling into which spots and linear modules click magnetically.
UGR (Unified Glare Rating)
A measure of discomfort glare from light fittings. Desk work calls for UGR 19 or less.
Uniformity
How even the light is across a surface, given as the ratio of minimum to average lux.

Chemicals (26)

Blending
Mixing two or more chemicals to a set formula to make a product for a customer's process, such as a cleaning solution or water treatment blend.
CAS number
The unique registry number the Chemical Abstracts Service assigns to each chemical substance, used to identify it without ambiguity (for example 64-17-5 for ethanol).
Certificate of analysis (CoA)
A batch document from the producer showing that the delivered chemical meets its specification, with test results for purity and impurities.
Commodity chemical
A chemical made in large volumes to a standard specification (for example caustic soda or sulphuric acid), bought mainly on price, purity and reliable supply.
Denatured alcohol
Ethanol with additives that make it undrinkable, so it can be used and taxed as an industrial solvent.
Drilling fluid additives
Chemicals added to drilling mud to control viscosity, density, fluid loss and shale stability while drilling wells.
Ethanol · also Ethyl alcohol
A clear, volatile alcohol (CAS 64-17-5) used as a solvent, disinfectant base and chemical intermediate. Supplied as rectified (about 95–96%), absolute or anhydrous (99.5%+) and denatured grades.
Flash point
The lowest temperature at which a liquid gives off enough vapour to ignite in air. Low flash point solvents need strict fire precautions.
Food grade
A grade that meets food additive specifications (such as FCC or E-number specifications) for use in food and beverages.
GHS
The UN Globally Harmonized System of classification and labelling of chemicals: common hazard classes, pictograms and SDS format.
Glycerine · also Glycerol, Glycerin
A sweet, viscous, water-soluble liquid (CAS 56-81-5) used in pharmaceuticals, personal care, food, resins and as a humectant. Sold as crude, technical and refined (USP) grades.
IBC (intermediate bulk container)
A reusable 1,000-litre (or similar) tank in a steel cage on a pallet, used to ship liquid chemicals.
Industrial chemicals
Chemicals used as raw materials, solvents, reagents or process aids in manufacturing, construction, oil and gas, water treatment and other industries.
MEK (methyl ethyl ketone) · also Butanone, 2-Butanone
A fast-evaporating ketone solvent (CAS 78-93-3) used in coatings, adhesives, printing inks, PVC cements and lube-oil dewaxing. Highly flammable.
Nitric acid
A strong mineral acid and oxidiser (CAS 7697-37-2) used for fertilisers, metal pickling and passivation, etching and chemical synthesis. Commercial grades are commonly around 55–68%.
Passivation
Treating stainless steel with an acid (often nitric or citric) to remove free iron and strengthen its protective chromium oxide layer.
Purity / assay
The percentage of the wanted substance in a product, measured by a stated method.
Safety data sheet (SDS) · also MSDS
The 16-section document under the UN GHS that gives a chemical's hazards, safe handling, storage, first aid and emergency measures. Every shipment should come with one.
Solvent
A liquid that dissolves other substances, such as ethanol, MEK, acetone or xylene in coatings, cleaning and extraction.
Specialty chemical
A chemical or blend bought for what it does (a surfactant, corrosion inhibitor or defoamer, for example) rather than its exact composition.
Technical data sheet (TDS)
A document giving a product's properties, typical values and uses, as opposed to its hazards (which are on the SDS).
Technical grade
A grade pure enough for industrial use but not certified for food, pharmaceutical or laboratory use.
Toll blending
Blending carried out by one company to another company's formula and specification.
UN number
A four-digit number identifying a dangerous good for transport, for example UN 1170 for ethanol solutions.
USP / pharmaceutical grade
A grade that meets a pharmacopoeia monograph (such as USP or BP) for purity and impurities, for medicines and personal care.
Water treatment chemicals
Coagulants, flocculants, biocides, scale and corrosion inhibitors and pH adjusters used to treat drinking water, process water, cooling water and wastewater.

Specification & standards (16)

BS 476
The older British fire test series. Parts 6 and 7 together give the "Class 0" rating still common in Gulf specifications.
CISCA
The Ceilings & Interior Systems Construction Association, whose Recommended Test Procedures for Access Floors define how concentrated, ultimate, uniform and rolling loads are tested.
EN 13501-1
The European reaction-to-fire classification for construction products, from A1 (non-combustible) to F, with smoke (s) and droplet (d) sub-classes.
EPD (environmental product declaration)
A verified document that reports a product's environmental impacts over its life cycle, used for LEED and other rating systems.
ISO 14001
The international standard for environmental management systems.
ISO 45001
The international standard for occupational health and safety management systems.
ISO 9001
The international standard for quality management systems.
LEED
A green building rating system from the US Green Building Council, widely used on Saudi projects.
MasterFormat
The standard numbering system for construction specifications. Raised access floors sit in section 09 69 00, carpet in 09 68 00, HVAC ducts in 23 31 00.
Material approval request (MAR)
The formal request on Saudi projects for the consultant to approve a material before it is used.
Method statement
A document that describes step by step how a system will be installed safely and to specification.
Mock-up
A sample installation built on site for approval of the finish, detailing and workmanship before full installation.
Mostadam
Saudi Arabia's own sustainable building rating system, run by the Ministry of Municipalities and Housing.
PSA MOB PF2 PS/SPU
The UK Property Services Agency specification for raised access floors, still widely referred to for light, medium, heavy and extra-heavy grades.
Saudi Building Code (SBC)
The national building code of Saudi Arabia, covering structure, fire protection (SBC 801), energy (SBC 601/602) and more.
Submittal
The package of data sheets, test reports, drawings and samples sent to the consultant for approval before materials are ordered.