Quality first. No exceptions.
Nordinfini lives and stands by the quality of what it makes and installs. Here is what that means in practice: the promises we keep, how we build quality into every step, and how we make responsibly.

“Quality is not a department at Nordinfini. It is the reason we exist. We would rather lose an order than supply something we would not put in our own building.”
Five promises we keep on every project
We do not cut corners to win on price
We price fairly for a product made properly. We will not drop a grade, thin a panel or swap a material to beat a cheaper quote.
We recommend the right product, not the cheapest one
For floors that means 4.5 kN as the minimum for offices: a stiffer floor is quieter, sounds solid and lasts longer. For ducts, insulation and lighting it means sizing to the project, not to the price.
We state what is tested, nothing more
Every load, fire and acoustic figure on our data sheets comes from a test standard or a manufacturer test report. Where a value still has to be confirmed, we say so.
We install to the method statement
Our own teams install to the method statement for each system: chemical anchoring up to 600 mm finished floor height, mechanical anchoring and stringers above it, and the partner’s instructions for every Kingspan and MIGUA system.
We put it right
If something we supplied is not right, we fix it. A defective panel, duct or fitting is repaired or replaced, never left on site.
From the first drawing to long after handover
Specify
Our technical team checks loads, finishes, finished floor heights, movement and U-values against the project before anything is quoted. For forklifts and MEWPs, Nord Floors engineering checks the wheel loads.
Make or source
Raised floor panels are made in-house in Dammam to tight tolerances (for nSteelCement: squareness 0.75 mm, flatness 1.0 mm diagonal), and pre-insulated HVAC ducts are fabricated in-house in Dammam on our own CNC line from Kingspan panels. Our carpets are produced to order in our own qualities. Building-envelope systems come from Kingspan and MIGUA, whose systems are independently tested.
Test
Raised floors are tested to the CISCA Recommended Test Procedures for Access Floors for concentrated, ultimate, uniform and rolling loads.
Install
Our own installation teams follow the method statement for each system and hand over with the documents the consultant needs.
Stand behind it
We stay reachable after handover, and we put right anything we supplied that is not right.
ISO 9001, 14001 and 45001
Quality, environment and safety are run as certified management systems, audited externally, valid to January 2029. Raised floors are load tested to CISCA; Kingspan and MIGUA systems carry their own approvals, such as FM, UL and AMCA, shown on each product page.
Making responsibly, in Dammam
Good quality and low waste go together: a floor that lasts the life of the building is the most sustainable floor. In our plant we also do the following.
Nothing washed away
Cement mix washed off in production is recovered and goes back into new mixes.
Refurbish before replace
Defective panels are refurbished or recycled; cut pieces are reused on site.
Recycled content
Our panel mix uses fly ash, a recycled by-product, documented in our recycled content letter.
Solar on the shop floor
Factory fans and cooling run on solar power.
Water used twice
An in-house wastewater treatment system lets us reuse grey water.
Cleaner driving
Our sales team drives electric and hybrid cars.
Giving back per square metre
For every square metre of raised floor we sell, we plant a tree and give a meal to a child in need.
Steel that comes back
The steel shell of our steel cementitious panels is fully recyclable at the end of the building’s life.
We are preparing an Environmental Product Declaration (EPD) for our raised access floors, with independent verification to follow.
Questions
Is Nordinfini ISO certified?
Yes. Nordinfini's management systems are certified to ISO 9001 (quality), ISO 14001 (environment) and ISO 45001 (occupational health and safety), valid to January 2029.
Which standard are Nord Floors raised floors tested to?
The CISCA (Ceilings & Interior Systems Construction Association) Recommended Test Procedures for Access Floors, for concentrated, ultimate, uniform and rolling loads.
Why does Nordinfini recommend 4.5 kN for offices?
A 4.5 kN panel is stiffer than lighter grades. It sounds solid underfoot, transmits less footfall noise and holds up better over the life of the building, so we recommend it as the minimum for every office.
Does Nordinfini have an Environmental Product Declaration (EPD)?
We are preparing an EPD for our raised access floors and plan to have it independently verified. Ask us for the recycled content letter and our plant sustainability practices in the meantime.