Nord Light selector

The right light for every room in the office

Pick the room, the ceiling and the mood. We rank the Nord Light fittings that suit it, show the light level and glare limit the room needs, and write the specification for your list.

1Which room?

2What ceiling?

Screens or video calls in the room?

3Set the mood

Slide from warm to cool. Recommended for this room: 4000K.

4000K
Warm 2700KNeutral 4000KCool 6500K

4Room size

Helps us size the layout. Rough guide only; we run a lighting calculation on your plan.

Target about 500 lux, UGR 19 or lower (EN 12464-1). For 96 m² that is roughly 96,000 lumens in total from the lights, allowing for losses.

5Your lights, best first

Show
NL-DL-301Top pick

Honeycomb Anti-Glare Downlight

A round ceiling light with the bulb sunk deep inside a honeycomb. You see the glow, not the dazzle. Our first choice for rooms with screens.

Meeting roomReceptionExecutive cabin

Very low glare (UGR below 19) · 60° spread, up to 50,000 hours · Samsung LEDs, aluminium housing · IP20, indoor · 5-year warranty

Colour
Power
Ceiling hole
NL-LN-101

Connectable Linear Light

A long, slim light you can join end to end into one continuous line, up to 3.6 m. Hang it, fix it to the ceiling or recess it. Corner and Y pieces let you draw shapes.

Open officeCorridorMeeting room

Soft panel cover, wide 110° spread · Easy to join with no gaps in the line · OSRAM LED chips, EAGLERISE driver · SASO energy label Grade A

Colour
Run length (joinable)
Power (depends on length)
Finish
Fitting
Connectors
NL-PN-201

Power-Select Panel 60×60

The classic square office panel with a bonus: choose 40, 50 or 60 W on the day to match the room. Colours look natural and true.

Open officeMeeting roomAnti-glare feel

Natural colours (CRI 95+) · Soft opal cover · 3-year warranty

Colour
Power (selectable)
Size
NL-PN-202

Everyday Panel 60×60

A plain, dependable square panel for offices and back-of-house rooms. Even light across the desks with a long warranty.

Open officePantryStore room

90° spread · Aluminium body · 5-year warranty

Colour
Power
Finish
Size

Options shown are what each light comes in. Availability, final specifications and pricing are confirmed in the quotation.

iLight in two minutes

Four things decide how a room feels. You can pick well knowing only these.

  • 1. Colour of the lightKelvin (K). 3000K warm white: reception, lounges. 4000K neutral white: offices, meeting rooms. 6000–6500K cool daylight: stores, plant rooms.
  • 2. Power and brightnessWatts (W) is the electricity used; lumens (lm) is the true brightness. Bigger rooms and higher ceilings need more watts per light or more lights.
  • 3. Spread of the lightBeam angle. A narrow 36° beam is a spotlight for a feature; a wide 110° beam lights a whole desk area evenly.
  • 4. GlareRated as UGR. Offices usually ask for 19 or lower; lower is more comfortable. Anti-glare lights hide the bright source in a deep cone or behind a soft cover.
Quick room guide
RoomColourLight levelGlare (UGR)Lights that suit it
Open office4000K500 lux19 or lowerNL-PN-201, NL-PN-202, NL-LN-101, NL-LN-102
Meeting room3000K to 4000K500 lux, dimmable19 or lowerNL-DL-301, NL-LN-103, NL-PN-201
Reception3000K300 lux22 or lowerNL-DL-301, NL-DL-304, NL-TR-401, NL-LN-102
Corridor4000K100 lux28 or lowerNL-LN-101, NL-PN-203, NL-DL-302, NL-DL-303
Executive cabin3000K to 4000K500 lux19 or lowerNL-DL-301, NL-LN-103, NL-TR-401
Pantry and breakout3000K to 4000KAbout 300 lux22 or lowerNL-LN-103, NL-PN-202, NL-DL-303
Feature wall3000KAccentNot applicableNL-TR-401, NL-DL-304

Light levels and glare limits follow EN 12464-1; all rooms need colour rendering CRI 80 or higher. Meeting-room lighting should be controllable.

Why Nord Light
  • Made for fit-outsOur range covers the lights an office fit-out actually uses.
  • Stock in Saudi ArabiaReady local stock for fit-out schedules that cannot wait for shipping.
  • One list, one supplierLights, switches and sockets, and raised access flooring quoted together for the same project.
  • Help choosingSend the room list. We suggest the light, colour and power for each space.

Questions

What colour of light is best for an office?

4000K neutral white for open offices and screen work; 3000K warm white for reception and lounges; 3000K to 4000K for meeting rooms and executive cabins. Cool daylight (6000–6500K) suits stores and plant rooms.

How bright should an office be?

EN 12464-1, which most Saudi fit-out specifications refer to, asks for about 500 lux on desks in offices and meeting rooms, 300 lux in reception and pantries, and 100 lux in corridors.

What is UGR and why does it matter?

UGR is the glare rating. Offices with screens usually need UGR 19 or lower, so people see the light without the dazzle. Anti-glare downlights and panels hide the bright source in a deep cone or behind a soft cover.

How many lights does a room need?

The selector gives a rough lumen total for the room. We run a lighting calculation on your reflected ceiling plan to set the final quantity and layout.

All about Nord Light →