Four raised access floor series made in Dammam: nSteelCement, nGroove, nHPL and nSDV. Load grades from 3.7 to 11.1 kN, tested to CISCA.

Four series, made in Dammam

Which raised floor do you need?

The floor finish decides the series; what the floor carries decides the grade. nSteelCement is our main series and takes every finish, from carpet to marble on a board layer. We recommend 4.5 kN as the minimum for every office.

The finish decides the series

Carpet tiles, LVT or SPCnSteelCement, laid straight onto the panel
Marble, stone, porcelain or parquetnSteelCement with a plywood, cement board or fibreboard layer (our standard). nGroove (premium) where the finish must be bonded straight to the panel
Antistatic floornHPL, final finish already on
Static dissipative floornSDV, final finish already on

The load decides the grade

Every series comes in the same CISCA-tested grades. General offices: 4.5 kN minimum. MEWPs and scissor lifts: 6.8 kN and above. Forklifts and stackers: heavy grades after a wheel-load check by Nord Floors engineering.

Not sure? The raised floor selector asks two questions and gives you the series, grade, understructure and specification text.

Load grades (all series)

GradeConcentratedImpactUltimateUniformRolling, 10 passesRolling, 10,000 passes
3703.7 kN0.6710.8 kN19.8 kN/م²3.0 kN2.2 kN
4504.5 kN0.6713.5 kN23.3 kN/م²3.6 kN3.0 kN
5605.6 kN0.6716.8 kN33.1 kN/م²4.5 kN3.6 kN
6806.8 kN0.6720.1 kN42.6 kN/م²5.6 kN4.5 kN
8908.9 kN0.6726.7 kN49.9 kN/م²6.7 kN5.6 kN
111011.1 kN0.6733.3 kN58.3 kN/م²8.9 kN6.7 kN

Recommended minimum for offices: the 450 grade (4.5 kN). For MEWP access: 680 (6.8 kN) and above. Tested to CISCA Recommended Test Procedures for Access Floors. nGroove starts at the 450 grade.

Compare the four series

nSteelCementnGroovenHPLnSDV
CoreSteel cementitiousHigh-density calcium sulphateSteel cementitiousSteel cementitious
FinishCarpet, LVT, SPC direct; stone on a board layerHard finishes bonded directlyAntistatic HPL, factory-appliedStatic dissipative vinyl, factory-applied
Thickness33 mm40 mm35 mm34.5 mm
Finished floor height80–2000 mm80–2000 mm80–2000 mm100–2000 mm
Load grades3.7 to 11.1 kN4.5 to 11.1 kN3.7 to 11.1 kN3.7 to 11.1 kN
FireA1A1, 120-minute integrity to EN 1366-6A1A1
AcousticIIC 58IIC 55IIC 58IIC 58
Pedestal headcrossroundflatsquare
StringersAbove 600 mm FFHAbove 600 mm FFHAlwaysAlways

Source: Nordinfini technical data sheets.

Understructure rules

  • nHPL and nSDV always sit on stringers.
  • nSteelCement and nGroove are stringerless up to 600 mm finished floor height, with stringers above it.
  • Up to 600 mm, pedestals are fixed with chemical (adhesive) anchoring; above 600 mm they are mechanically anchored to the slab.
  • Pedestal heads by series: nSteelCement cross head, nGroove round head, nHPL flat head, nSDV square head.
Pedestals and accessories →

Why steel cementitious for Saudi buildings

Steel cementitious (nSteelCement, nHPL, nSDV)Woodcore (chipboard)
CoreLightweight cementitious core in a welded steel shellCompressed wood-chip board
FireNon-combustible, A1Combustible, typically Bfl to Dfl
MoistureDoes not swellMade for dry conditions; swells and weakens if wet
Load range3.7 to 11.1 kNMany systems light to medium grades
End of lifeSteel shell fully recyclableBoard disposal
Data centres and server rooms

How many perforated panels do you need?

Perforated panels and air grilles are sold by the piece, finished to match the floor around them. Our calculator takes the airflow from your cooling unit datasheet and tells you how many, step by step.

Perforated raised floor panel on four pedestals

Questions consultants ask

Why does Nord Floors recommend 4.5 kN as a minimum?

Lighter grades can carry ordinary office loads, but a 4.5 kN panel is stiffer. It sounds more solid underfoot, transmits less footfall noise and holds up better over the life of the building. We recommend 4.5 kN as the minimum for every office.

Can I put marble or stone on a raised floor?

Yes. nSteelCement is our standard panel and takes marble, stone, porcelain and parquet: fix a plywood, cement board or fibreboard layer to the panels, then lay the finish on it. Carpet tiles, LVT and SPC go straight onto the panel. nGroove is our premium panel for projects that need the hard finish bonded straight to the panel with no board layer.

Can a MEWP or scissor lift be used on a raised access floor?

Yes, on 6.8 kN grades and above. Nord Floors floors at 6.8 kN carry MEWPs on site today. Forklifts and pallet stackers are possible on heavy grades after Nord Floors engineering checks the wheel loads.

When does a raised floor need stringers and mechanical anchoring?

nHPL and nSDV are gravity-laid systems, so they use stringers at every height, from the lowest. nSteelCement and nGroove are corner-locking systems, fixed to the pedestal heads at each corner, so they need stringers only above 600 mm finished floor height. Up to 600 mm, chemical (adhesive) anchoring of the pedestals is enough; above 600 mm, pedestals are mechanically anchored to the slab.

Which standard are Nord Floors raised floors tested to?

Nord Floors follows the CISCA (Ceilings & Interior Systems Construction Association) Recommended Test Procedures for Access Floors for concentrated, ultimate, uniform and rolling loads.

Is woodcore (chipboard) raised flooring suitable for Saudi Arabia?

Usually not the best choice. Woodcore panels have a compressed wood-chip (chipboard) core, made for dry indoor conditions. Coastal humidity in Jeddah and Dammam, water from cleaning or leaks, and wet works during construction can make the core swell and lose strength. Woodcore is combustible (typically Bfl to Dfl fire classes), and many woodcore systems are rated only at light to medium grades. Steel cementitious panels such as nSteelCement are non-combustible (A1), do not swell with moisture, carry 3.7 to 11.1 kN, and last the life of the building; the steel shell is fully recyclable at end of life.

When do I need nHPL or nSDV?

Only where the room needs antistatic (nHPL) or static dissipative (nSDV) flooring, such as data rooms, server rooms and control rooms. Both come with their final finish factory-applied.

How many perforated panels or air grilles does a room need?

Only as many as the cooling needs. They are sold by the piece, not by the square metre. Divide the airflow that reaches the floor (cooling units running, minus leakage) by the airflow one panel passes at the design underfloor pressure. Our perforated panel calculator walks you through it from your CRAC datasheet.

Is Nord Floors raised flooring made in Saudi Arabia?

Yes. All four series are manufactured by Nordinfini in Dammam Industrial Area 2 and supplied across Saudi Arabia and the GCC.