Expansion joints & louvres · Glossary
Watertight expansion joint
A joint cover with a sealed centre insert and connection sheets bonded into the waterproofing, so water cannot pass through the joint. Used on car park decks, podiums, kitchens and pools.
Related terms in Expansion joints & louvres
- Build-up height
- The thickness of screed and finish above the structural slab that a joint profile or trim sits in. Floor joint covers come in set heights, so the build-up decides which height to order.
- Connection sheet
- The flexible flanges on each side of a watertight joint that are bonded into the waterproofing: long sheets for bitumen, short sheets for coatings, fleece-laminated sheets for liquid membranes.
- Thermal movement
- Expansion and contraction caused by temperature change, estimated as Δ = α × L × ΔT. Concrete expands about 8 to 12 millionths of its length per °C, so 30 m of exposed slab with a 55 °C swing moves about 18 mm.
- Replaceable centre seal
- The elastic insert in the middle of a joint cover that takes the movement and keeps water out, and can be changed without breaking out the floor.
- Total movement
- How far the joint opens and closes in total, written as a figure (20 mm), as plus or minus (±10 mm) or as a percentage of the joint width. A cover must take at least this movement.
- Contraction joint
- A narrow joint cut or formed in a slab to control shrinkage cracking. All-metal covers protect its edges from forklift and hard-wheel traffic.
- Joint width
- The gap between the two parts of the structure at the joint, set by the structural engineer. MIGUA tables give it as bf max: the widest gap a cover takes.
- Joint fire barrier
- A blanket or foam barrier fitted in the joint gap where it crosses a fire compartment floor or wall, tested to UL 2079 for its rating and movement.