Contraction joint

A narrow joint cut or formed in a slab to control shrinkage cracking. All-metal covers protect its edges from forklift and hard-wheel traffic.

Related terms in Expansion joints & louvres

Replaceable centre seal
The elastic insert in the middle of a joint cover that takes the movement and keeps water out, and can be changed without breaking out the floor.
Joint fire barrier
A blanket or foam barrier fitted in the joint gap where it crosses a fire compartment floor or wall, tested to UL 2079 for its rating and movement.
Connection sheet
The flexible flanges on each side of a watertight joint that are bonded into the waterproofing: long sheets for bitumen, short sheets for coatings, fleece-laminated sheets for liquid membranes.
Wheel load
The load one wheel puts on a joint cover. Joint load tables list air-filled tyres, solid plastic tyres and hard wheels separately, usually on a 200 × 200 mm contact patch.
Watertight expansion joint
A joint cover with a sealed centre insert and connection sheets bonded into the waterproofing, so water cannot pass through the joint. Used on car park decks, podiums, kitchens and pools.
Surface-fixed joint cover
A cover screwed on top of the existing floor instead of being set in the screed, used in refurbishments where the floor cannot be broken out.
Build-up height
The thickness of screed and finish above the structural slab that a joint profile or trim sits in. Floor joint covers come in set heights, so the build-up decides which height to order.
Beginning point of water penetration
In AMCA 500-L, the free-area velocity at which 0.01 oz of water per ft² of free area starts to come through a louvre in a 15-minute test. Select louvres well below it.