Car park soffit insulation: how thick does it need to be?
A bare 200 mm concrete slab loses heat at a U-value of about 3.4 W/m²K. Here is how much soffit insulation it takes to reach common targets — and why the board you choose changes the answer.

Short answer: for a typical 200 mm concrete slab over a car park, about 50 mm of phenolic board (Kingspan Kooltherm K10) reaches a U-value of 0.40 W/m²K, and about 70 mm reaches 0.30. A stone wool slab needs roughly one and a half to two times that thickness for the same result.
Why insulate the soffit at all?
Rooms above an open or ventilated car park sit on a cold (or, in Saudi summers, very hot) slab. A bare 200 mm concrete slab has a U-value of roughly 3.4 W/m²K — it lets heat straight through. Insulating the underside keeps the room above comfortable and cuts cooling load, without touching the finished floor.
Thickness for common targets
Calculated for a 200 mm concrete slab, with standard surface resistances. Use the soffit insulation selector for your own slab and target.
| Target U-value (W/m²K) | Phenolic (Kooltherm K10) | Stone wool slab (70 kg/m³) |
|---|---|---|
| 0.50 | 40 mm | 60 mm |
| 0.40 | 50 mm | 75 mm |
| 0.35 | 60 mm | 100 mm |
| 0.30 | 70 mm | 130 mm |
| 0.25 | 80 mm | 130 mm |
Thin board or non-combustible slab?
- Phenolic board gives the thinnest build-up, which matters where headroom for vehicles and services is tight. Its white foil face can stay exposed as the finished soffit.
- Stone wool is non-combustible and adds sound absorption, at the cost of thickness.
Phenolic is not an A1/A2 non-combustible product, so the choice must be checked against the project’s fire strategy. Our selector shows both options side by side for exactly this reason.
Fixing
Soffit boards are mechanically fixed to the slab with insulation fixings at the spacing the manufacturer specifies, with joints tight and taped where foil-faced. Plan service penetrations before boarding to avoid cutting finished work.
Frequently asked questions
Does the insulation need a finish? Foil-faced phenolic boards can be left exposed. Stone wool is usually supplied with a glass-fibre veil facing.
Who supplies Kooltherm K10 in Saudi Arabia? Nord WPI supplies Kingspan Kooltherm K10 as an authorised Kingspan partner.
Size the envelope system for your project
Soffit insulation by U-value, pre-insulated ducts and MIGUA joints — each with its own selector.
See Nord WPI selectorsRelated articles

UL 181, ASTM E84 and Class 0: duct fire ratings explained
The fire tests behind duct specifications in the Gulf, what each one actually measures, and what to ask for in a submittal.

How to choose an expansion joint profile
Joint width, movement, traffic and fire rating — the four facts you need before choosing an expansion joint cover for floors, walls, ceilings or roofs.

Kingspan KoolDuct vs PalDuct: choosing pre-insulated ductwork in Saudi Arabia
KoolDuct, PalDuct Phenolic, PalDuct PIR: what each Kingspan duct system is, how they differ on insulation, fire rating and operating limits, and how to pick one for a Saudi project.